1. System Application
DCU10 full digital color Doppler ultrasound scanner is available for the diagnosis of abdomen (including GYN and OB), cardiology, vessel and small parts, with the following scanning mode: 2D, CFM, PDI,PW and M to provide the best resolution and sensitivity.
Support convex probe, linear probe and transvaginal probe, etc.
2. General Specification
2.1 Dimension: 400 mm(L)´186mm(W)´ 385mm(H), N.W.: 8.8 Kg (without probe)
2.2 Power Supply: Dual power-supply system: AC110/230 -15%~+10%,60/50Hz±1Hz;Battery:large capacity(6.6Ah)Li-battery 1 PC,120 minutes life work.
2.3 Display: 10.4″ high definition & flicker free color medical LCD monitor
Description
DCU10 Full Digital Color Doppler Ultrasound scanner
3.2 Operating mode
B、B/B、4B mode, M、B/M mode, CFM, PDI, PW, THI
3.3 Probe socket: 2
3.4 Media & peripheral device
USB flash card
Video printer: UP-897MD
Color laser printer (defined model:HP Color LaserJet CP1515n、
HP Color LaserJet CP1525n)
TV Output:PAL/NTSC
3.5 Storage
Image storage, cine loop storage, cine loop ≥300 frames, 16G hard disk storage
3.6 Puncture Guide Line: Adjustable angle and memory storage
3.7 Languages, Menu operation: Chinese / English / Russia / Portuguese
4. System Setting
- Basic setting
Language:English / Chinese, Date: yyyy-mm-dd or mm-dd-yyyy or dd-mm-yyyy, Time: 24 hours, Body mark:≥131, Image store format:PNG、BMP, Time setting, Key tone setting, PAL / NTSC setting
Character brightness setting
- Note setting:including pathological change, OB, routine, abdomen, GYN, Small parts, Cardiology. Towards every item, preset major terms, you can add or correct to edit when necessary.
- Storage setting:image format selection
- Exam part setting:adjustable emission power, PRF setting (preset stationary parameters according to different exam part.), adjustable Doppler angle, adjustable sample volume, adjustable linear array deflection, adjustable base line, adjustable filter wave.
5. Acoustic beam processing
Full digital acoustic beam technology, real time point-to-point dynamic receiving focus, continuous dynamic focus, real time dynamic adjustable variable aperture imaging technology,real time dynamic acoustic beam apodization, dynamic filtering, numerical control dynamic frequency scanning
5.1 Digital channels:32
5.35.2 Image processing : IE:0~3, Frame correlation:0~3, IE(gamma correction):0~7, Compressing curve:0~7
6. Scanning parameters
6.1B Mode
B acoustic output:25%、50%、75%、100%, B Gain:0~127, Dynamic:27~100dB, Scanning:higher frame rates, high density, frequency conversion:4 classes, harmonic wave:2 classes
6.2M Mode
M acoustic output:25%、50%、75%、100%, M Gain:0~127, M Dynamic:27~100dB, M scanning speed:1~8 classes adjustable, M adjustable & visual sampling line, M operating mode::scroll & scan, Scanning:higher frame rates, high density, frequency conversion:4 classes, harmonic wave:2 classes
6.3CFM color Doppler mode
CFM Gain:0~127, Max PRF:7.5kHz, Min PRF:0.35kHz, Color frequency:2 classes adjustable, CFM wall filter:8steps 50-350Hz, Color persistence:4 steps, Color threshold: 6 kinds, Color balance: 16 steps, Sensitivity:6 kinds, CFM color smoothing:3 steps, Adjustable linear array color deflection
6.4PDI Power Doppler Mode
PDI Gain:0~127, PDI wall filter:4 steps, 50-350Hz, PDI color smoothing:3 steps, Max PRF:7.5kHz, Min PRF:0.35kHz, Adjustable linear array color deflection
6.5PW Spectrum Doppler Mode
PW Gain:0~127, PW Dynamic:8steps 0-120, PW Wall filter:8steps 50-350Hz, Sampling volume width:0.5-20mm, Angle correction, Base line adjustment:7 steps, Max PRF(Speed):7.5kHz, Min PRF(Speed):0.35kHz, Speed ruler:8 steps
6.6Image diplay
256 grades gray scale 2D image diplay, gray scale histogram plot display, Image reservation:up/down, right/left, Depth scope:32~252 mm (35 grades) each probe has its own depth scope and adjustable grades, Focus: continuous dynamic focus, dynamic aperture, Dynamic: ≥100dB (visual & adjustable), M mode speed: 8 classes adjustable, Display TGC curve, Black & white related, Video output: NTSC or PAL
7. Measurement / Calculation
7.1General measurement
B Mode measurement: distance, area (distance measurement method, ellipse distance method, trace method), circumstance (distance measurement method, ellipse distance method, trace method), volume (two – axial method), angle , Histogram , sectional view, stenosis rate( length stenosis rate, area stenosis rate ) and depth.
M mode measurement: depth, slope, heart rate, circle
D mode measurement: velocity, heart rate, flow velocity, time acceleration, Pulse/ Resistance Index, Max differential pressure, PG mean,ratio, stroke volume, flow rate.
7.2 Gynecology measurement and analysis:uterus, endometrium, ovary, cervix, follicle.
7.3 Obstetric measurement and analysis
BPD)、CRL、GS、FL、HL、TAD、TTD、
7.4 Urology measurement and analysis:Prostate volume, Residual Urine Volume
7.5 Cardiology measurement and analysis
Measurement items in B Mode, B/B Mode, CFM Mode, PDI Mode:
Left Ventricle function Measurement、may calculate cardiac output CO、 May calculate Military Vector Chart Format MVCF、May calculate cardiac index CI and stroke index SI;
Right Ventricle diameter RV measurement, Main pulmonary PA measurement
Measurement items in M, /B/M Mode:
Left Ventricle function, Mitral valve:EFLSP and AC descent velocity measurement、Ratio E/A and mitral valve orifice volume QMV measurement, Aorta, Cardiac output CO, Ejection time ET, Left Ventricle myocardial weight LVMW
Measurement items in PW Mode:Velocity、Heart rate、time, Acceleration, Pulse/ Resistance Index, Max differential pressure], PGmean, Ratio, stroke volume, flow rate
Measurement report:
Obstetric measurement report,, gynecology measurement report,, cardiology measurement report,, urology measurement report and other measurement reports, Automatically store measurement results and generate report
8.1 Body mark
131 kinds of body marks with probe position, which can be quickly selected by intuitive and detailed body mark interface;
Text mark can preset text content; Arrow mark supports multiple arrow marks and adjustable direction
Standard configuration:
Main unit:1 pc
Double probe sockets, automatically identify probe, 3.5MHzmulti-frequency abdomen convex probe:1pc, 6.5MHz multi-frequency trans-vaginal probe:1pc, 7.5MHz multi-frequency high linear probe:1pc