8L Autoclaves Sterilizer Electric Heated Autoclave Steam Sterilizer

$129.00

Description

Product Description

  • Made of high quality 304 stainless steel, which is durable and practical.
  • The use of wrought iron flange reinforcement makes the pot body more stable and safe.The double scale pressure gage simultaneously display the temperature and pressure value in the display pot.
  • Working temperature: 126-128 Celsius degree; working pressure: 0.145-0.165 Mpa. The self expanding seal has a good sealing effect.
  • This sterilizer will not stop heating once it is working and can’t be timed as well. Please watch for it when it is working in case of water in pot boiled away. Otherwise, autoclave may break down.

Technical Specifications

PRODUCT LINE: BGroyallove
COLOUR: Beige
WEIGHT (KG): 7.65
SIZE (L X W X H CM): 37x37x30

Operation:

Step 1.Place the sterilizer on a flat surface.

Step 2.Open the lid, take out the inner tank of sterilizer (you can see the heating electric tube),add water to the heating tube above 3.5L, you must add enough water in time to avoid burning the electric tube due to lacking of water.

Step 3.Put those items need to sterilize into the sterilization room, you should keep gaps between the items. Do not block steam holes of the safety valve, air releasing valve, and finally cover the lid, tighten the screws.

Step 4. After the normal operation of the equipment, when the measured temperature reaches 105 degrees, open the air releasing valve to discharge cold air inside the sterilizer. When the air releasing valve start going out a little hot steam, close the air releasing valve.

Step 5. When the steam pressure reaches 0.142-0.165MPa , the safety valve will start pressure relief work, in order to maintain a certain pressure.

Step 6. After sterilization, unplug the power cord. 3 minutes later, open the air releasing valve, when the pressure gauges to zero, open the lid to discharge the remaining air. Safety Measure and Maintenance 1. This sterilizer is steam pressure vessel so do not impact in using and forbid overpressure. If the pressure pointer of pressure gauge reaches the 0.165MPa and the safety valve does not exhaust, it should stop using at once and check up the safety valve. 2. The pointer should be at zero position before usage the pressure gauge, otherwise the gauge has been failure and it should repair or replace the gauge. The pressure gauge should be regulated 1~2 times per year, ensuring sensitiveness and correctness. 3.Gasket is easy to wear. If it does not work well, see it whether become aging and hard, then replace it in time.