  • 15″ Multiparameter Patient Monitor MD9015T

15″ Multiparameter Patient Monitor MD9015T

$1,008.00

MD9015Touch screen 15 inch patient monitor 192-hour trend graph,1000 group of blood pressure list,ST segment measurements, arrhythmia analysis and more functions,
Support up to 32 TCP/IP network connection,composed of a central information system..
Comes with remote control

Category:

Description

15″ Multiparameter Patient Monitor MD9015T

Product Features 

15” high resolution color TFT display with maximum 13 waveforms
Full touch-screen enables intuitive operation by clicking on the specific parameters
of the waveform in real time, standard configuration includes the navigation knob
Pacemaker detection, electrosurgical interference proof
Defibrillation protection and defibrillation synchronization
SD Card slot enable memory extension for large data storage
USB and serial port enable abundant future upgrades
VGA output and Analog output
OxyCRG available to judge the respiration and circulation function for neonate
Large font display
Arrhythmia and S-T segment analysis
Built-in rechargeable Li-ion (6hours maximum with 2x 4200mAh batteries)
Nurse Call function and bi-directional communication with MFM-CMS central station
Multi language: English/Simplified Chinese/Traditional Chinese/Spanish/Czech/Italian/Polish/French/German/Brazilian/Portugese/Russian.
Standard configuration: 3/5-lead ECG, NIBP, SpO2, RESP, 2-Temp, PR
Optional: 12-lead ECG, Nellcor-SpO2, Omron NIBP, 2-IBP/4-IBP, Mainstream/Side stream CO2,
CO, Multi-Gas, Full Touch Screen, Thermal Recorder, WLAN Accessory
Large Data Storage: 120 hours graphic and tabular trends of all parameters; 1200 sets of NIBP
 measurement and 70 alarm events; 2-USB ports and SC card slot ensure data storage/function upgrades.
Clinical data can be viewed and managed via Patientcare viewer software (To be released)
Clinical network: bi-directional communication with CMS-2000 central station by wired or wireless connection
Complete and flexible mounting solution for ICU and operation room. High-end parameters for more flexible clinical applications.
MD9015T Support:
DC power input and to adapt to a variety of environmental conditions
External recorder can print the recorded waveform data and other information in real time
External the EtCO2 interface can be connected to the mainstream CO2 module to facilitate the clinical needs
Drug concentration in titration calculations to support the event functions to customize and record
Up to 32 TCP / IP network connection composed of a central information system
Wireless networking

patient monitor 15inch touch screen

Options 
Invasive Blood Pressure (IBP)
Carbon dioxide (CO2) Module
Masimo SpO2 Module
Thermal Printer

Product Specification

Electrocardiogram (ECG)

Input mode Five-lead ECG input / three-lead ECG input
Lead selection I, II, III, aVR, aVL, aVF, V-
Gain selection AUTO,0.25X,0.5X,1X,2X,4X
Operating mode Diagnostic mode, monitoring mode, operation mode
Calibration signal 1mV ±5%
Protection The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference of electric knife. Anti-defibrillation protection.
Pacemaker at the same time use Support
Electrode off instructions Each electrode (RL excluded)
Scanning speed 12.5mm/s, 25 mm/s, 50 mm/s
Common mode rejection ratio ≥90dB
Input impedance ≥5.0MΩ

Heart Raterate (HR)                          

Measuring range Adult 30 ~ 300bpm, newborns 30 to 350 bpm
Resolution 1 bpm
Accuracy < ±5bpm
Heart rate sensitivity ≥0.20mVp-p
Alarm range 15 to 350 bpm, upper and lower limits
Alarm indication Audible and visual alarm, display the data and parameters flashing display alarm
message text prompts, there are three levels of alarm

Pulse Oximetry
SPO2 Range:                          1% to 99%
Resolution:                              1%
Accuracy:                                70% to 99% range: ±2%;
1% to 69% range:                    ±5%;
Method:                                  Dual wavelength LED

ST-segment

ST-segment measurement range -2.0~+2.0mV
ST-segment measurement accuracy Within the range of -0.8 ~ +0.8 mV: ± 0.02mV or reading± 10%,
Whichever is greater; Other range: undefined
Resolution 0.01mV
ST-segment update cycle 10s
ST segment alarm range -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable

 
Arrhythmia analysis

Arrhythmia types 13 kinds of (scalable)

Respiration Rate
Rate:                                  2 to 120 bpm (CO2)
Resolution:                        1 breath/min

NIBP (Non-invasive Blood Pressure)
Technique:                        Oscillometric during inflation
Range:                               Adult/Pediatric: 40 to 240 mmHg
Neonate:                           10 to 150 mmHg
Measurement Cycle:         < 40 sec. typical
Automatic Measurement
Cycles (Selectable):          2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
STAT Mode:                      5 minutes of continuous readings
Max. Allowable Cuff
Pressure: Adult:                300mmHg
Pediatric:                          240 mmHg;
Neonate:                          150 mmHg
Resolution:                       1 mmHg
Transducer Accuracy:       ±2 mmHg or ±2% of reading,
Heart (Pulse) Rate
Range:                              30 to 250 bpm
Accuracy:                        ±2 bpm or ±3%, whichever is greater

EtCO2 technological index

Interface form External interface
Range of
measurement
0~10 kPa or (0~75) mmHg
precision(error) (0kPa~5.4kPa) the error is ±0.3kPa、
(5.5kPa~10.0kPa)the error is ±0.7kPa
Alarm upper limit 2.1~13.2 kPa
Alarm lower limit 0~6.5 kPa
time 12s
EtCO2 exist
Unit kPa / mmHg / %
Compatibility external main stream and side stream are compatible
IBP technological index
Measured channel Single way and double way are optional
Range of
measurement
SYS: 6.7kPa~32.0kPa(50mmHg~240mmHg)
MEAN: 3.4kPa~26.6kPa(26mmHg~200mmHg)
DIA: 2.9kPa~24.0kPa(22mmHg~180mmHg)
Mean error ≤±0.4kPa (±3mmHg)
Range of alarm SYS:  upper limit   0.3kPa~53.3kPa(2mmHg~400mmHg)
Lower limit   0kPa~53.1kPa(0mmHg~398mmHg)
MEAN:  upper limit    0.3kPa~53.3kPa (2mmHg~400mmHg)
Lower limit   0kPa~53.1kPa (0mmHg~398mmHg)
DIA:    upper limit    0.3kPa~53.3kPa ( 2mmHg~400mmHg)
Lower limit   0kPa~53.1kPa ( 0mmHg~398mmHg)
Measured unit mmHg/kPa
Specification of
sensor
DPT-248(space)
Consumables mode SCW-UTAH-01