$1,008.00
MD9015Touch screen 15 inch patient monitor 192-hour trend graph,1000 group of blood pressure list,ST segment measurements, arrhythmia analysis and more functions,
Support up to 32 TCP/IP network connection,composed of a central information system..
Comes with remote control
Description
15″ Multiparameter Patient Monitor MD9015T
Product Features
Options
Invasive Blood Pressure (IBP)
Carbon dioxide (CO2) Module
Masimo SpO2 Module
Thermal Printer
Product Specification
Electrocardiogram (ECG)
Input mode | Five-lead ECG input / three-lead ECG input |
Lead selection | I, II, III, aVR, aVL, aVF, V- |
Gain selection | AUTO,0.25X,0.5X,1X,2X,4X |
Operating mode | Diagnostic mode, monitoring mode, operation mode |
Calibration signal | 1mV ±5% |
Protection | The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference of electric knife. Anti-defibrillation protection. |
Pacemaker at the same time use | Support |
Electrode off instructions | Each electrode (RL excluded) |
Scanning speed | 12.5mm/s, 25 mm/s, 50 mm/s |
Common mode rejection ratio | ≥90dB |
Input impedance | ≥5.0MΩ |
Heart Raterate (HR)
Measuring range | Adult 30 ~ 300bpm, newborns 30 to 350 bpm |
Resolution | 1 bpm |
Accuracy | < ±5bpm |
Heart rate sensitivity | ≥0.20mVp-p |
Alarm range | 15 to 350 bpm, upper and lower limits |
Alarm indication | Audible and visual alarm, display the data and parameters flashing display alarm message text prompts, there are three levels of alarm |
Pulse Oximetry
SPO2 Range: 1% to 99%
Resolution: 1%
Accuracy: 70% to 99% range: ±2%;
1% to 69% range: ±5%;
Method: Dual wavelength LED
ST-segment
ST-segment measurement range | -2.0~+2.0mV |
ST-segment measurement accuracy | Within the range of -0.8 ~ +0.8 mV: ± 0.02mV or reading± 10%, Whichever is greater; Other range: undefined |
Resolution | 0.01mV |
ST-segment update cycle | 10s |
ST segment alarm range | -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable |
Arrhythmia analysis
Arrhythmia types | 13 kinds of (scalable) |
Respiration Rate
Rate: 2 to 120 bpm (CO2)
Resolution: 1 breath/min
NIBP (Non-invasive Blood Pressure)
Technique: Oscillometric during inflation
Range: Adult/Pediatric: 40 to 240 mmHg
Neonate: 10 to 150 mmHg
Measurement Cycle: < 40 sec. typical
Automatic Measurement
Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
STAT Mode: 5 minutes of continuous readings
Max. Allowable Cuff
Pressure: Adult: 300mmHg
Pediatric: 240 mmHg;
Neonate: 150 mmHg
Resolution: 1 mmHg
Transducer Accuracy: ±2 mmHg or ±2% of reading,
Heart (Pulse) Rate
Range: 30 to 250 bpm
Accuracy: ±2 bpm or ±3%, whichever is greater
EtCO2 technological index
Interface form | External interface |
Range of measurement |
0~10 kPa or (0~75) mmHg |
precision(error) | (0kPa~5.4kPa) the error is ±0.3kPa、 (5.5kPa~10.0kPa)the error is ±0.7kPa |
Alarm upper limit | 2.1~13.2 kPa |
Alarm lower limit | 0~6.5 kPa |
time | 12s |
EtCO2 | exist |
Unit | kPa / mmHg / % |
Compatibility | external main stream and side stream are compatible |
IBP technological index | |
Measured channel | Single way and double way are optional |
Range of measurement |
SYS: 6.7kPa~32.0kPa(50mmHg~240mmHg) MEAN: 3.4kPa~26.6kPa(26mmHg~200mmHg) DIA: 2.9kPa~24.0kPa(22mmHg~180mmHg) |
Mean error | ≤±0.4kPa (±3mmHg) |
Range of alarm | SYS: upper limit 0.3kPa~53.3kPa(2mmHg~400mmHg) Lower limit 0kPa~53.1kPa(0mmHg~398mmHg) MEAN: upper limit 0.3kPa~53.3kPa (2mmHg~400mmHg) Lower limit 0kPa~53.1kPa (0mmHg~398mmHg) DIA: upper limit 0.3kPa~53.3kPa ( 2mmHg~400mmHg) Lower limit 0kPa~53.1kPa ( 0mmHg~398mmHg) |
Measured unit | mmHg/kPa |
Specification of sensor |
DPT-248(space) |
Consumables mode | SCW-UTAH-01 |