• Home
  • Shop
  • Contec ECG 1200G Electrocardiograph

Contec ECG 1200G Electrocardiograph

$658.00

Standard Accessories

1 ground wire
1 set limb electrode clamp
1 paper roll
1 set chest electrodes
Power connection
USB connection
Software (same languages as internal software)
Manual: GB, FR, IT, ES

Category:

Description

12 Lead Digital ECG EKG Machine
Model:ECG1200G Brand:CONTEC
Contec ECG1200g 12 Lead Digital ECG EKG Machine Ce
Features

1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including auto 12×1, auto 6×2+1, auto 6×2+1_H, auto 6×2, auto 6x2_H, auto 3×4+1, auto 3×4+2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.
4)Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
5)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
6)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
7)Multi-language(Turkish, French, Chinese, English, German, Kazakstan, Polish, Portuguese, Russian, Slovenian, Spanish and Ukrainian) interface and report.
8)In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, record up to 300 ECG waveform(commonly, it is 3s case), which meets the requirements of visiting a patient at home and body examination.
Screen size 8 inches
Leads 12 leads
Input way Floating and defibrillation protection
Lead Standard 12 leads(model:BIP0057)
Patient leak current <10µA
Input impedance ≥50MΩ
Frequency response 0.05Hz~150Hz(-3dB)
Time constant Time constant>3.2s
CMRR >60dB, >100dB( Adding filter)
EMG interference filter 35Hz(-3dB)
Recording way Thermal printing system
Specification of recording paper 210mm(W)*20m(L) high-speed thermal paper
Paper speed Auto record: 25mm/s, 50mm/s, error:±5%
Rhythm record: 25mm/s, 50mm/s, error:±5%
Manual record:5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, error:±5%
Sensitivity selections 2.5,5,10,20,40mm/mV, error:±5%. Standard sensitivity is 10mm/mV±0.2mm/mV.
Auto record Record setup according to auto record format and mode, automatically changing leads, measuring and analysing.
Rhythm record Record setup according to rhythm record format and mode, automatically measuring and analysing.
Manual record Record setup according to manual record format, manually changing leads.
Measurement parameters HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P A*is, QRS A*is, T A*is, R(V5) , S(V1) , R(V5)+S(V1)
Product safety type Class I CF applied part; there is defibrillation and pacing protection circuit in it.
Enduring polarization voltage ±300mV
Noise level ≤15µVp-p
Fuse specification 2 pcs φ5*20mm AC time lag; T1.6A/250V(Power supply 220V)
Size 340mm(L)*320mm(W)*85mm(H)
Net Weight 3.2Kg
Accessories
Standard:
-A lead cable
-A limb electrode
-A chest electrode
-A thermal recording paper
-A power cord
-An earth wire
-A user manualOptional:
-ECG-Sync software+USB cable
-ECG electrode
-Bag
-Conductive paste
-USB cable
-3G card
-Wi-Fi card
-Remote Operation Guide