• Home
  • Shop
  • S6100D Anesthesia System Adult and Pediatric

S6100D Anesthesia System Adult and Pediatric

Application:

The Anesthesia machine makes a good performance in Intensive Care Units (ICU), Operation room,
Anesthesiology Department and other departments. S6100D is designed for ease of use, incorporating
basic function and the maximum patient safety in daily anesthesia practice. Professional design for
adult, child and infant inhalation anesthesia and respiratory management, with advanced ventilation
mode. Combine proven ventilation technology with the latest refinements in ergonomics and systems
integration with an advanced, easy to use anesthesia table designed together with experienced experts
to streamline your anesthesia workflow.

Category:

Description

S6100D Anesthesia System Adult and Pediatric

S6100D Anesthesia System Adult and Pediatric

Flowmeter
Rapid oxygen supply
Tidal volume (Vt)
Frequence
I:E
PEEP
Pressure triggering sensitivity Ptr
Flow trigger sensitivity Ftr
SIGH
Apnea ventilation
Pressure limit
O2 (0.110 L/min)
N2O (0.110 L/min)
25 L/min75 L/min
0, 20 mL1500 mL
1 /min100 /min
2:11:6
0 cmH2O30 cmH2O
20 cmH2O0 cmH2O Based on PEEP
0.5 L/min30 L/min
0 (off) 1/1005/100
OFF5s60s
20 cmH2O100 cmH2O
Ventilator parameter range
Frequence
Tidal volume (Vt)
MV
Oxygen concentration
0 /min100 /min
0 mL2000 mL
0 L/min100 L/min
15 %100 %
Monitoring parameter
P-T (pressure – time)
F-T (flow – time)
Oscillogram
Gas source
Pressure
Voltage
Power frequency
O2, N2O
280 kPa600 kPa
100240V
50/60 Hz
Working condition
Wooden case packing size
G.W.
N.W.
L 740* W 800* H 1460mm
98KG
66KG
Packing size
IPPV, A/C, SIMV, SIGH, MANUAL
Ventilation mode
,
ADULT · PEDIATRIC Friendly Powerful Reliable
The AC power failure alarm
Low voltage alarm for back up battery
No tidal volume
High oxygen concentration alarm
Low oxygen concentration alarm
High airway pressure alarm
Low airway pressure alarm
High minute volume alarm
Low minute volume alarm
Continuous pressure alarm
Suffocation warning
The maximum limited pressure
Fan error
Oxygen deficit
Power failure or no connection
11.3±0.3V
≤5mLwithin 6s
19%100%
18%99%
20 cmH2O100 cmH2O
0 cmH2O20 cmH2O
Adult (5 L/min20 L/min)
Paed (1 L/min15 L/min)
010 L/min
(PEEP+1.5 kPa) over 16s
5s60s no spontaneous ventilation
12.5 kPa
Show on screen
Show on screen
Alarm and protection
The picture is for reference only. For more information, please contact Superstar Medicalsales representatives.
Nanjing Superstar Medical Equipment Co., Ltd.
Address: No.6 Building, No.9 Bofu Road, Yanjiang Industrial Development Zone, Liuhe District, 211505 Nanjing, P. R. China.
Tel+86-25-69658833 Mobile+86-13813361534 Fax: +86-25-69658833
EmailRicky005@superstar-med.com Webhttp://www.superstar-med.net
Other models for your reference: